Why is my pentair spa heater not working?
Possible Cause: Low or restricted water flow through heater. Suction leak allowing air into the water flow. Low water flow when switched to spa mode or the control is not in spa mode.
What’s the error code on my Sta Rite heater?
If it checks out ok and the heater stays off and in service heater mode have a look at the back of the control board. Down the side of the board are error message lights that sometimes can point in the right direction for diagnosis. I have a sta rite max e therm 400 displaying an error code 128 r14.
What’s the difference between a Pentair and Sta-Rite pool heater?
Just another way that Sta-Rite built a radically different heater. A completely redesigned pool heater that allows the Pentair MasterTemp and Sta-Rite Max-e-Therm heaters to be over 50% smaller in size and footprint. I sincerely hope that this post has helped you solve your pool heater problem!
Is the mastertemp pool heater the same as the Max-E therm?
The controls and circuit boards for the Max-E-Therm and the MasterTemp are fairly identical. Even the new MasterTemp aboveground pool heater has the same design, and the same troubleshooting procedure. The error codes below can get you started with understanding what your heater is trying to tell you.
What’s the error code on my Sta Rite pool pump?
I have a sta rite max e therm 400 displaying an error code 128 r14. Pool pump kicks on, the heater fires up, runs for a very short period of time, shuts down for a short time, then fires back up, and shortly turns off again.
If it checks out ok and the heater stays off and in service heater mode have a look at the back of the control board. Down the side of the board are error message lights that sometimes can point in the right direction for diagnosis. I have a sta rite max e therm 400 displaying an error code 128 r14.
Just another way that Sta-Rite built a radically different heater. A completely redesigned pool heater that allows the Pentair MasterTemp and Sta-Rite Max-e-Therm heaters to be over 50% smaller in size and footprint. I sincerely hope that this post has helped you solve your pool heater problem!
The controls and circuit boards for the Max-E-Therm and the MasterTemp are fairly identical. Even the new MasterTemp aboveground pool heater has the same design, and the same troubleshooting procedure. The error codes below can get you started with understanding what your heater is trying to tell you.
What does R13 mean on a Star rite pool heater?
Shawn the R13 signifies the revision of the PWA on startup or reboot. If the membrane pad switches to spa when the heater ignition sequence is complete and the main burner is running and you can’t switch it back to pool then there could be an issue with the membrane pad and or PWA.