I was called out to look at a Pentair MasterTemp 400 pool heater in Newport Beach today. After running for about 15 minutes, the display showed E05. Diagnostics registered stack flu sensor error.
What causes a Pentair mastertemp 400 error code E05?
I see more E05 errors that are due to things like a sooted exchanger (fuel delivery, venting), scaled up exchanger (water side), or a low water flow. I see those problems a lot more than a sensor that has gone bad. I could even buy that continued high temps could eventually cause a SFS to fail.
Why do I get an E05 error on my Pool?
E05: E05 errors can be due to things like a sooted exchanger (fuel delivery, venting), scaled up exchanger (water side), or a low water flow.
Why is my Pentair mastertemp heater not working?
In this case, the thermal regulator had already been changed out, so unless the heat exchanger was plugged up (possible, but not likely) or the pump/filter had an issue- which I saw no sign of- I wouldn’t? suspect a water flow problem. ? What I did notice as soon as I walked in the yard, was the tiny gas meter (pictured).
I was called out to look at a Pentair MasterTemp 400 pool heater in Newport Beach today. After running for about 15 minutes, the display showed E05. Diagnostics registered stack flu sensor error.
I see more E05 errors that are due to things like a sooted exchanger (fuel delivery, venting), scaled up exchanger (water side), or a low water flow. I see those problems a lot more than a sensor that has gone bad. I could even buy that continued high temps could eventually cause a SFS to fail.
Why does my water heater give an E05 code?
The NT will give this code for other reasons also, such as low gas pressure, blocked orfices or inadequate air flow. The MasterTemp stack flue snsor trips when exhaust temps reach more than 350 degrees. This is usauly caused by a flow issue or a bad thermal regulator causing the water to remain in the exchanger and over heat.
What does E05 mean on a Pentair minimax NT?
I have a Pentair Minimax Nt and the E05 error is igniter/flame/pilot failure. I have the same problem with mine right now. Not sure if you all have gotten help yet, but the mastertemp E05 error code is related to the stack flue sensor and the NT is, like posted, the flame sensor code.
What should I do if my Pentair pool filter is not working?
You can also order any Pentair pool filter parts Complete the cleaning process by removing all sand or diatomaceous earth from inside. Replace filter media and let the filter cycle a few times. Take care not to stuff filter media inside. Ideally, the quantity should be sufficient to keep the pressure correct.
What kind of pool heater does Pentair use?
Pentair pool heaters come from the legacy of the Purex-Triton Minimax heater, when Pentair purchased the Purex company. In 2004, Pentair acquired the Sta-Rite company and it’s Max-E-Therm heater technology.
How to troubleshoot a Pentair mastertemp pool heater?
Our Pentair Mastertemp Troubleshooting Guide starts with the error codes shared by both models, and follows into a 6 page flowchart to step by step troubleshoot a Pentair or Sta-Rite pool heater, and get it firing again fast! The burners on this type of MasterTemp/Max-e-Therm heater are quite unique from previous generation pool heaters.
What does error code E05 mean on Pentair pool heater?
The heater is a Master Temp 250 if that helps at all. garrygoeson : Yes that helps alot! the heater I was refering to is totally different then the one you have. The EO5 error code on the Master Temp says that you have an “open stack flue switch or sensor.
E05: E05 errors can be due to things like a sooted exchanger (fuel delivery, venting), scaled up exchanger (water side), or a low water flow.
What is the error code for Pentair maximum temp 400?
Pentair Maximum Temp 400 – error code E05…occurs repeatedly after 8 mins…tried to hold down the pool button to reveal more info…after 20 secs nothing but E05…Service Heater light is lit…checked the wires – good condition…cleaned the contacts albeit they did not appear to need it…no change…pls advise…merely replace the sensor or…
When does the Pentair pool heater shut down?
The heater comes on for about 45 seconds and then shuts down with that code. Show More Show Less Ask Your Own Pool and Spa Question Share this conversation Answered in 3 hours by: 7/1/2012 Pool and Spa Expert: garrygoeson, Home Appliance Technician replied 8 years ago garrygoeson, Home Appliance Technician Category: Pool and Spa
What causes the E04 error code on a Pentair blower?
The blower may turn on and the heater may fire up for a few seconds, but will turn back off within a few seconds. A couple of things can trigger the E04 error code that you should check for:
Pentair Maximum Temp 400 – error code E05…occurs repeatedly after 8 mins…tried to hold down the pool button to reveal more info…after 20 secs nothing but E05…Service Heater light is lit…checked the wires – good condition…cleaned the contacts albeit they did not appear to need it…no change…pls advise…merely replace the sensor or…