Why does my Sundance spa not turn on?
The Sundance book says it is a faulty flow switch but it seems like the circ pump would still function even if the flow switch was bad. Bill put the pump on the bench and run 240vac to it. If it doesn’t run you could have a bad pump. the TB1 terminal block and then power up the spa. If the pump doesn’t run you could have a bad pump.
What kind of error does Sundance certa 780 have?
My Sundance Certa 780 Series hot tub is showing an error of FL1. I went through the manual diagnostics and the error is still there. I contacted Aquatech and they suggested I clean the filter with the FilterBrite.
Where is the FL1 code on a Sundance spa?
The hose is secured with a small gear clamp. Once the air lock is alleviated you should see water flow (bubbles) returning to your return heat jet (small grated fitting) in the footwell of your spa directly under your filter housing next to the larger suction grate. The FL1 msg should also go away and your heat light should turn on.
What to do if you have an airlock on your Sundance spa?
Remove your filter and stick the garden hose in that hole with a rag wrapped around it to force water into that line and hopefully alleviate a potential airlock. Alternatively you could locate the suction line where it is attached to the circulation pump, loosen the gear clamp and the hose and bleed the airlock from there.
What kind of circulation pump does Sundance Spa use?
Note: This test only works on 850 Series with Circulation Pump prior to 2001: Try turning the #1 pump which is 2 speed.
How often should I Run my Sundance spa?
Most people run your Series of Sundance spa in Standard mode with a 24hr circ pump run time 12 months a year. Setting it up this way and always having a clean micro filter lessens the chance of the water chemistry and water clarity getting away on you. Also make sure that your ClearRay Uv lamp has not expired and or your ozone is still operational.
How can I test my Sundance spa Aqua-Tech?
Clay power down the spa and disconnect the two wires going to the psi switch. Power up the spa again and test the switch with your ohm meter. Put one probe on each each leg of the psi switch. With the circ pump on you should have continuity. With the circ pump off you should have an open switch and no continuity.
Note: This test only works on 850 Series with Circulation Pump prior to 2001: Try turning the #1 pump which is 2 speed.
The Sundance book says it is a faulty flow switch but it seems like the circ pump would still function even if the flow switch was bad. Bill put the pump on the bench and run 240vac to it. If it doesn’t run you could have a bad pump. the TB1 terminal block and then power up the spa. If the pump doesn’t run you could have a bad pump.
What are the manuals for the Sundance spa?
Find out how to use, care for, and program your Sundance ® spa by browsing the manuals and guides below. (2020) 880™ Series Manual – (Aspen®, Maxxus®, Optima®, Cameo®, Altamar®, Marin®, Cambria™, Capri®) (2020) 780™ Series Manual – (Chelsee®, Hamilton™, Montclair™, Bristol™, Hanover®, Dover™)
What kind of electricity does a Sundance Hot Tub need?
Most Sundance spas must be connected to 240V electrical service, but some offer the option of operating on either 120V or 240V. While connecting to 120V can be less involved, most customers prefer the benefits of the 240V spa, which include quicker heating time and better temperature maintenance during cold weather use.
Most Sundance spas must be connected to 240V electrical service, but some offer the option of operating on either 120V or 240V. While connecting to 120V can be less involved, most customers prefer the benefits of the 240V spa, which include quicker heating time and better temperature maintenance during cold weather use.
What to do if your Sundance spa heater is not turning on?
Heater is deactivated and pump may not turn on. Flow/pressure switch is defective. These steps should only be taken after checking and testing the above steps. With the circ pump and the main pump off, test switch operation with an ohmmeter in the continuity position, test for continuity across switch terminals.
What should the circulation pump settings be on a Sundance spa 880?
I have a Sundance Spa 880 Series at my new residence and I am wondering what the recommended setting is for the filter/circuation pump. Currently it is set on “Standard Mode” and continuously runs. In my previous residence I had an Arctic Spa that was set to circulate intermittently.
Most people run your Series of Sundance spa in Standard mode with a 24hr circ pump run time 12 months a year. Setting it up this way and always having a clean micro filter lessens the chance of the water chemistry and water clarity getting away on you. Also make sure that your ClearRay Uv lamp has not expired and or your ozone is still operational.