Why does my pilot light keep going out on my RV water heater?

Why does my pilot light keep going out on my RV water heater?

The most common reason that your pilot light on your water heater keeps going out is a damaged, bent or dirty thermocouple.

Why does my Atwood water heater not ignite?

There are several issues behind why your Atwood Rv water heater doesn’t ignite. In this chapter, we break down every possible cause and provide the solution as well. A thermocouple is a device that senses the heat of a pilot and lets the gas flow to the burner.

What causes pilot outage on Atwood water heater?

A blocked U-tube can also cause pilot outage. Clean the tube and get rid of any obstruction there is. You should check the gas pressure and ensure it is in accordance with the recommendation of the manufacturer, in this case, Atwood.

What kind of tank does Atwood water heater have?

Additionally, Atwood water heaters have aluminum tanks that act as anode rods, thus the situation is a bit different for these. Now that you know the essentials about your onboard RV water heater, Dave has a few extra expert tips for operating and maintaining your specific unit.

Why does the pilot light go out on my water heater?

A thermocouple is a device that senses the heat of a pilot and lets the gas flow to the burner. If the thermocouple is malfunctioning, it doesn’t allow the gas to run through the pilot and the burner. In return, the pilot light goes out repeatedly and would not stay lit.

Why is my Atwood RV water heater not working?

Bad Circuit Board Atwood Rv water heaters are famous for their faulty circuit boards. The design of it is horrible. If there is a problem with your circuit board, it won’t allow the gas to pass.

A blocked U-tube can also cause pilot outage. Clean the tube and get rid of any obstruction there is. You should check the gas pressure and ensure it is in accordance with the recommendation of the manufacturer, in this case, Atwood.

What to do if your RV water heater wont light?

The Eco switch wires up between the control board and the gas valve. It is also attached to the thermostat. If it gets faulty, no power will pass to the gas valve. In return, your RV water heater will not ignite. Firstly, remove one of the wires on the ECO and check its continuity with VOM. Make sure it shows you 12 volt on the meter.

A thermocouple is a device that senses the heat of a pilot and lets the gas flow to the burner. If the thermocouple is malfunctioning, it doesn’t allow the gas to run through the pilot and the burner. In return, the pilot light goes out repeatedly and would not stay lit.