Why does my pilot keep blowing out?
If your furnace pilot light keeps going out, it’s likely you have a broken thermocouple in your gas furnace. The thermocouple is a rod that comes into physical contact with the flame in your system. When this component is not able to detect the flame, it will close the gas valve to prevent a gas leak in your home.
Can a pilot light blow out in the wind?
When it does get windy, which is fairly often, the pilot light will blow out. You can see it fluttering around with a gust of wind, and it works perfectly when it’s calm, so I’m positive it’s the wind. I’ve also had a tech come out and check everything as far as operation.
What to do if your furnace pilot light blows out?
If your furnace has a standing pilot light, you may experience some frustration with it blowing out on windy days. We have compiled a few tips you can try to fix the problem. The best cure is electronic ignition. However, electronic ignition is not feasible nor cost-effective for most standing pilot furnaces.
Why is the pilot light blowing out on my water heater?
You may have faced a situation where whenever it gets windy, the water heater’s pilot gets blown out. Check if your thermocouple is dirty, clogged, damaged, or worn out, and repair it. Also, a downdraft coming from your air vent may cause the problem. The water heater pilot light is a small flame that ignites the gas burner on your water heater.
What causes a gas pilot light to go out?
You have a chimney and need a cap. Someone improperly installed your firebox cover. The most common issue that causes your pilot light to go out continually relates to your thermocouple. Otherwise known as the flame sensor, the thermocouple automatically shuts off the gas if the pilot light goes out.
Why is my pilot light not staying lit?
The primary reason a pilot light won’t stay lit is simply equipment malfunction. If you’ve checked everything else and the light continually goes out, this is probably the cause. In this case, you may need to replace your pilot light. A pilot light can also keep going out because of a problem with the thermocouple .
Why does my furnace pilot light keep going out?
If your furnace pilot light keeps going out, it’s likely you have a broken thermocouple in your gas furnace. The thermocouple is a rod that comes into physical contact with the flame in your system. This component will deactivates the gas when the pilot light goes out.
Why does your pilot light go out?
However, if the light goes out frequently there could be other issues. Some of the possible serious reasons for pilot lights to go out include loose or broken gas valves, thermocouples or heat exchangers, faulty venting, low gas pressure, or high winds.
How do pilot lights work?
Pilot lights serve a fairly straightforward purpose in gas furnaces; they ignite the gas that’s flowing through the furnace in order to create heat. When the furnace is turned on, gas flows from a valve into the burner, where it is lit. A small amount of gas is also fed from a valve into the pilot light, which is how it keeps burning all the time.