Why does my lazy spa say error?

Why does my lazy spa say error?

The E02 error code can occur when the filters are dirty or blocked. KINKED OR BENT LINER PIPES.

When do I get FL1 flashing on my Sundance spa?

HI, I just plugged in my Sundance spa and I’m getting the code FL1 flashing. Even before I hit any buttons. When I go to turn pump 1 on both speeds work.

How to troubleshoot a flashing Flo for a spa?

First verify your spa is receiving the specified incoming voltage into the circuit board as well as out of the circuit board to the transformer. Also, check all fuses for continuity. Next, check the service tag on the side of your circulation pump. This will tell you approximately what voltage your circulation pump should be getting.

What does it mean when your spa says FL1?

January 31, 2014. Reply. Dan typically when you have an FL1 code it means the spa is not heating and won’t heat until the FL1 code is addressed so you want to check with an external thermometer if your water is 72 degrees.

Why is my FL1 code flashing on my PWA?

The FL1 msg should also go away and your heat light should turn on. If it does not you could have blockage in your circ pump line or circ pump housing. Check to clear blockage if you suspect this. If there is no blockage check for voltage with your multimeter at your circ pump points on the PWA in the Sentry control box.

Why is the FL1 code flashing on my Sundance spa?

the TB1 terminal block and then power up the spa. If the pump doesn’t run you could have a bad pump. I have a 2004 Sundance Lagunas Spa that also has the Fl1 error code. I have had them in the past, and was able to reset it with the hose up to the intake trick on many occasions, but not this time.

First verify your spa is receiving the specified incoming voltage into the circuit board as well as out of the circuit board to the transformer. Also, check all fuses for continuity. Next, check the service tag on the side of your circulation pump. This will tell you approximately what voltage your circulation pump should be getting.

What does FL1 code mean on a spa heater?

When FL1 code starts flashing it means the flow switch is malfunctioning and stuck open-likely because of a dirty filter or because there is an air lock problem at the circulation pump intake.When FL2 code starts flashing it means the flow switch isn’t working and it is stuck closed. In both cases, the spa heater will deactivate.·

The FL1 msg should also go away and your heat light should turn on. If it does not you could have blockage in your circ pump line or circ pump housing. Check to clear blockage if you suspect this. If there is no blockage check for voltage with your multimeter at your circ pump points on the PWA in the Sentry control box.