Where is the GFCI on a tiger river spa?

Where is the GFCI on a tiger river spa?

Cord-Connected 115 volt, 20 amp models:The GFCI is located at the end of the power cord. Before each use, with the unit operating, push the TEST button. The unit should stop operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI by pushing the RESET button.

Where is the GFCI on a 115 volt hot tub?

To ensure proper operation of this important safety device, test according to the following instructions per electrical configuration. Cord-Connected 115 volt, 20 amp models:The GFCI is located at the end of the power cord. Before each use, with the unit operating, push the TEST button.

Where is the serial number on a hot spring?

They are trained professionals who are familiar with the product as well as new spa ownership concerns. Their expertise will facilitate the enjoyment of your new Hot Spring spa. The serial number label is located within the equipment compartment of your Hot Spring spa.

When to disconnect power from tiger river spa?

Disconnect the power until the fault has been identified and corrected. NOTE:Failure to wait 30 seconds before resetting the GFCI may cause the spa’s Power Indicator (on the control panel) to blink. If this occurs, repeat the GFCI test procedure.

How do you check the water temp in a spa?

• Check the water temperature with an accurate temperature thermometer. Remove the spa cover and allow the water to cool. Adding cool water may be necessary. Touch any button to reset the system. If the water is still hotter than the set temperature]

When to use Spa when temperature is flashing?

Do not use spa when temperature is flashing or the OH message is displayed. HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F. SEoP = Sensor open or disconnected. Heater disabled but the spa is operational. SESH = Sensor short, nonfunctional.

What are the error codes on the spa side?

Flow Switch (heater is deactivated. Pump may also be deactivated). Panel sensors have been pressed too many times in a short period of time. Circuit Board temperature has exceeded acceptable limit. Freeze protection. No action is necessary. Freeze protection. No action is necessary. Communication between the panel and circuit board is faulty.

When does spa go into dry or priming mode?

(Displays on the 5th occurrence of “HFL” message with 24 hours). Heater is shut down, but other spa functions run normally. dr = Inadequate water detected in heater. dry = Inadequate water detected in heater. (Displays on third occurrence of “dr” message). Spa is shut down. Pr = When spa is first actuated, it will go into Priming Mode.