What to do if your Ecostar pump is not working?

What to do if your Ecostar pump is not working?

It is NOT an indication that something is wrong with the pump or drive. Shut off the breaker supplying the EcoStar with power for at least 2 minutes, verify screen is blank, then restore power. Inspect pump display The error has now cleared. If error frequently reoccurs AND pump is controlled by Hayward automation, proceed to step 1C.

Where is the Hayward Ecostar variable speed pump located?

I’m in Cedar Park, TX (Outside of Austin) and had a pool put in last Winter (filled Feb, 2013). I have had pretty consistent issues with the Hayward Ecostar Variable Speed Pumps. I have a Pro Logic Panel that controls it. I continually have a Drive Error!

Why is my Hayward variable speed pool pump not working?

Hayward said that sometimes there isn’t enough plumbing and the pressure shuts down the pump. This is a pretty big builder in Austin, and they don’t think that is the issue. Plus, the pump runs at 100% from 7am to 11am on Timer 1 with no problem. Which pump are you having trouble with? **Hayward Variable Speed Ecostar, it’s the pool pump.

Why does my Hayward pump run at 2933 rpm?

The strange thing is it usually occurs in the afternoons, during timer 3, and not in the morning. Hayward came out and suggested that we limit it to 2933 RPM vs full of 3450, saying the plumbing possibly can’t handle. It seems to handle it fine all morning on Timer 1, it runs at 3450 without issue for 4 hours.

It is NOT an indication that something is wrong with the pump or drive. Shut off the breaker supplying the EcoStar with power for at least 2 minutes, verify screen is blank, then restore power. Inspect pump display The error has now cleared. If error frequently reoccurs AND pump is controlled by Hayward automation, proceed to step 1C.

How many wires are on a Ecostar pump?

Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on the pump to 4 to the controller as shown (fig 22 & 23). Reinstall plugs. Wire colors can be different as those shown as long as they match point to point. Control Data Plug Pump Terminal Data Plugs Figure 23 Figure 22 Page 10 8 7 2 3 1 4

What kind of software do I need for Ecostar Aqua logic?

Software versions necessary to operate the EcoStar Aqua Logic/Pro Logic/Aqua Plus v2.65 or higher OnCommand 1.00 or higher E-Command 4(Original E-Command not compatible) v2.80 or higher 1. Maximum 500‟ for data cable The data cable needs to be run through the second (data) conduit opening and channel (Page 8).

What can Prologic do for a Hayward pool?

Pool owners can automate all work intensive functions such as filtration, heating, sanitization, balancing PH, and cleaning. ProLogic is offered in three different models for the right level of control to suit pool owner’s needs. Thanks for reading! We hope this helped you solve your Hayward needs.