What kind of valve actuator does Jandy use?

What kind of valve actuator does Jandy use?

Jandy Pro Series 2440 valve actuator designed for use with 2-port and 3-port valves. Prevents dead-heading of pumps. Corrosion-proof enclosure with external service switch.

What are the specifications of the JVA 2444?

These fully adjustable actuators offer versatile pool/spa automation with easy setups. All actuators work with the Jandy AquaLink®RS Control Systems and are available in 24 volt units. JVA 2444 Specifications Voltage 2 VAC Amperage 0.75 AMPS Cycles 60 Hz Wire Black Red White -conductor Common Switch Leg Switch Leg Figure 2.

Where are the teeth on a Jandy pool Valve?

3.JVA’s mount directly on all full-size Jandy Valves Turn the actuator over so you can see into the clear actuator shaft. There are four (4) “teeth” on the inside of the shaft. Locate the smallest “tooth” and align this “tooth” with the smallest slot on the valve (see Figure 5). Figure 4. Remove Locking Knob and Lid Screws Figure 6.

How to install a JVA on a pool Valve?

Place the actuator onto the valve. 5. Rotate the actuator while keeping the two shafts engaged until the screw holes on the actuator legs align with the empty screw holes (from step 2) in the valve (see Figure 6). 6. Use the four (4) large 2″ Phillips head screws (included with the JVA) to secure the JVA to the valve. 7.

Jandy Pro Series 2440 valve actuator designed for use with 2-port and 3-port valves. Prevents dead-heading of pumps. Corrosion-proof enclosure with external service switch.

What is the voltage of a JVA 2444 valve?

JVA 2444 Specifications Voltage 24 VAC Amperage 0.75 AMPS Cycles 60 Hz Wire Black Red White 3-conductor Common Switch Leg Switch Leg Figure 2. Standard JVA Mounting A B (Common Port) C A B (Common Port) C Figure 1.

Is it OK to use inauthentic Jandy replacement parts?

Use Genuine Factory Parts—It Does Matter! Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Plus, the use of inauthentic parts voids all factory warranties. Inauthentic parts may appear to be suitable on the surface, but they often fall short of factory standards.

Where is the plumbing position on a JVA?

3.1 Standard JVA Position Standard Plumbingposition is with the middle port (B) as the incoming or common port to the valve (see Figure 1). Standard Mountingposition is with the main body of the actuator over port B (see Figure 2).