What is the most common… What is the most common ignition fault cause on a Jandy LRZ above ground heater? It turns on for 5 seconds, then shuts off. Submitted:8 years ago. Category: Pool and Spa Show More Show Less Ask Your Own Pool and Spa Question Share this conversation Answered in 6 minutes by: .

Why does my Jandy pool not fire up?

The Jandy rep came out and we tried to wiggle the wires but could not get the heater to fire up. He checked the gas pressure and noticed that there was a spike in pressure and then it would come down to 9.7. Then the heater fired up . After 3 tries the heater would not fire up.

Where is the flame sensor on a Jandy?

poolguy810 :Check flame sensor first, its a small metal rod right by the hot surfaced ignitor with a single black wire connected to the ignition control on ign/fs. Terminal, stands for flame sensor. Try cleaning it up and re installing it to see if that helps. Customer: Flame sensor was dirty, with a bad crimp on it. Fixed it.

Where is the ignition control on a Jandy pool heater?

The ignition control is the covered plastic box with terminals each side? Flame sensor, and igniter are connected to the ignition control. Also check that you have a good ground to chassis for the transformer. Looks like the yellow lead from the trans former which is also connected to the ignition control.

What is the most common… What is the most common ignition fault cause on a Jandy LRZ above ground heater? It turns on for 5 seconds, then shuts off. Submitted:8 years ago. Category: Pool and Spa Show More Show Less Ask Your Own Pool and Spa Question Share this conversation Answered in 6 minutes by: 6/8/2012

What’s the problem with my Jandy pool heater?

Hello My Jandy LRZ pool heater… My Jandy LRZ pool heater is giving a “check IGN control” fault after two years of problem free use. what are my options? Thanks. Chrys Experience: Licensed construction supervisor with 45+ yrs. experience. Welcome to Just Answer, my name is ***** ***** I will do my best to help you with your issue.

poolguy810 :Check flame sensor first, its a small metal rod right by the hot surfaced ignitor with a single black wire connected to the ignition control on ign/fs. Terminal, stands for flame sensor. Try cleaning it up and re installing it to see if that helps. Customer: Flame sensor was dirty, with a bad crimp on it. Fixed it.

How to check IGN steps on Jandy JXI pool?

Carefully check to be sure no wires came loose and reconnect if they did. Reset breaker and allow the RS 12 to power up. Start the heater at it’s control panel. The ignition sequence begins and when fan starts watch the sight glass on the igniter until it turns red indicating that the start sequence is ready to light the heater.