What is the FL1 error code for Sundance spa Constance?

What is the FL1 error code for Sundance spa Constance?

We have a Sundance Spa Constance (2011) and today also noticed the FL1 error code. In addition to the code, noticed that the pool is registering 72 degrees when it is set to 101. We have never had a problem with the hot tube, until now. We changed the UV bulb last summer and changed out the filters. Any assistance would be helpful.

What does FL2 mean on a hot tub?

While an FL1 error code means the spa isn’t sensing enough water flow to close the flow switch, the FL2 error code means exactly the opposite. So when you are troubleshooting an FL2 error code, we want to determine why the spa thinks the flow switch, or the pressure switch, is providing a closed circuit instead of an open circuit.

What does FL1 code mean on a spa heater?

When FL1 code starts flashing it means the flow switch is malfunctioning and stuck open-likely because of a dirty filter or because there is an air lock problem at the circulation pump intake.When FL2 code starts flashing it means the flow switch isn’t working and it is stuck closed. In both cases, the spa heater will deactivate.·

What is the National Electrical Code for Sweetwater?

7)ELECTRICAL SUPPLY:The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with section 422-20 of the National Electrical Code, ANSI/NFPA 70.

We have a Sundance Spa Constance (2011) and today also noticed the FL1 error code. In addition to the code, noticed that the pool is registering 72 degrees when it is set to 101. We have never had a problem with the hot tube, until now. We changed the UV bulb last summer and changed out the filters. Any assistance would be helpful.

While an FL1 error code means the spa isn’t sensing enough water flow to close the flow switch, the FL2 error code means exactly the opposite. So when you are troubleshooting an FL2 error code, we want to determine why the spa thinks the flow switch, or the pressure switch, is providing a closed circuit instead of an open circuit.

What happens when Sundance spa goes into watchdog?

When the spa goes into the Watchdog the spa will not operate. This is how it happens: When you try to use the spa, you will see 3 or 4 dashes on the control panel (depends upon the model). If you try and reset your breaker, sometimes it comes on but it will probably go back into Watchdog error – – – -.

When FL1 code starts flashing it means the flow switch is malfunctioning and stuck open-likely because of a dirty filter or because there is an air lock problem at the circulation pump intake.When FL2 code starts flashing it means the flow switch isn’t working and it is stuck closed. In both cases, the spa heater will deactivate.·