What does the J1850 code mean in autocodes?
J1850 this is the OBD protacol, which the ECM communicated at this speed to a scan tool this is not a code. A engine code will have a “P” such as P0XXX or P1XXX this is just the communication speed. Please log in or register to add a comment.
How to check for short to ground on J1850?
When Monitored: While the ignition is on. Set Condition: The ECM detects a short to ground on the J1850. Turn the ignition off. Disconnect the ECM harness connectors. NOTE: Check connectors – Clean/repair as necessary. Measure the resistance between the (D25) J1850 circuit in the ECM harness connector and battery negative.
Is the resistance of the J1850 circuit less than 10 ohms?
Measure the resistance between the (D25) J1850 circuit in the ECM harness connector and battery negative. Is the resistance less than 10 Ohms? No –> Replace the ECM . Measure the resistance between the (D25) J1850 circuit and all other circuits in both ECM connectors.
J1850 this is the OBD protacol, which the ECM communicated at this speed to a scan tool this is not a code. A engine code will have a “P” such as P0XXX or P1XXX this is just the communication speed. Please log in or register to add a comment.
When Monitored: While the ignition is on. Set Condition: The ECM detects a short to ground on the J1850. Turn the ignition off. Disconnect the ECM harness connectors. NOTE: Check connectors – Clean/repair as necessary. Measure the resistance between the (D25) J1850 circuit in the ECM harness connector and battery negative.
Measure the resistance between the (D25) J1850 circuit in the ECM harness connector and battery negative. Is the resistance less than 10 Ohms? No –> Replace the ECM . Measure the resistance between the (D25) J1850 circuit and all other circuits in both ECM connectors.
When to turn off short to ground on J1850?
When Monitored: While the ignition is on. Set Condition: The ECM detects a short to ground on the J1850. Turn the ignition off. Disconnect the ECM harness connectors.