What does SW open on pool heater mean?
The heater will only operate for a short time before it cuts off and displays the message “Water Sw Open.” Even if the water flow in the pool intake and return appear normal, it still may be possible the flow could be restricted enough to not allow the pressure switch to close and therefore stop the heater from firing.
Where is the rollout switch on a Raypak pool heater?
Sounds odd that you turn it on and the switch is open. The rollout switch connects inside the cabinet right behind where the gas pipe comes into the gas valve. I have seen a few cases where the installer moved the rollout switch so they could install the gas pipe and they failed to put it back in place.
Why does my pool heater say Water SW open?
garrygoeson : I’m sorry to hear that. Usually, the Water sw open code is related to a flow problem, and may not be a fault with the heater. PLCUSTOMER: Right, I know there is some kind of regulator, for lack of a better word, and not sure if that is related to this, but I had problems with it on my last heater and the pool people removed it.
What is the purpose of a pressure switch on a pool heater?
The purpose of the pressure switch is to ensure that water is flowing through the unit before it allows the heater to turn on. The pool pump must be ON and your filter clean for the switch to close and allow voltage to pass through.
Why does Raypak pool heater display error : Water SW open?
The heater will only operate for a short time before it cuts off and displays the message “Water Sw Open.” I googled this and most seem to advise an adjustment to the water pressure switch. Do you agree and if so, where is it located and how do I adjust it. If you do not agree, what do you suggest? Show More Show Less
Why is the rollout switch open on my Raypak pool heater?
It may be a good idea to contact the installer and see if they are a warranty person for Raypak so they can diagnose what has caused the issue. Could just be high winds but it would be no cost to find out for sure. JACUSTOMER-zdajpyq1- : There is a a red plug right behind the gas pipe. I have disconnected the two plugs and reconnected them.
garrygoeson : I’m sorry to hear that. Usually, the Water sw open code is related to a flow problem, and may not be a fault with the heater. PLCUSTOMER: Right, I know there is some kind of regulator, for lack of a better word, and not sure if that is related to this, but I had problems with it on my last heater and the pool people removed it.
When do you roll out the roll out switch?
Here is what I found in the manual: Roll Out Sw Open – Rollout Switch – verify gas pressure, combustion air, blocked heat exchanger, proper vent size/connections, high wind conditions. The rollout switch is activated when something like wind causes the flames to shoot out towards the front of the unit.
What kind of pool heater does Raypak use?
We bought a new heater this season, a Raypak 206,000 BTU NG Electric Heater RHM-15-9962. It heated the pool nicely earlier in the week, but we turned it off when a cool spell was forecast. This morning I tried to turn it on and I get this error message: “Rollout SW Open”.