What does it mean when pool heater says SW open?
The heater will only operate for a short time before it cuts off and displays the message “Water Sw Open.” Even if the water flow in the pool intake and return appear normal, it still may be possible the flow could be restricted enough to not allow the pressure switch to close and therefore stop the heater from firing.
Why does Raypak pool heater display error : Water SW open?
The heater will only operate for a short time before it cuts off and displays the message “Water Sw Open.” I googled this and most seem to advise an adjustment to the water pressure switch. Do you agree and if so, where is it located and how do I adjust it. If you do not agree, what do you suggest? Show More Show Less
Why does my Raypak heater not light the pilot?
I turn it on and hear the ignition trying to light the pilot light but the pilot does not light. Clogged orifice? If so, can these be unclogged with a lighter or do they need to be disassembled?
What should the spark be on a Raypak pool?
Note: you should get ~28-32V between the PV and the MV/PV connections on the gas valve during pilot IGN. No spark AT THE point of ign.
Are there cookies on my Raypak pool heater?
Don't knmow\ – Answered by a verified Pool and Spa Expert We use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policyunless you have disabled them.
The heater will only operate for a short time before it cuts off and displays the message “Water Sw Open.” I googled this and most seem to advise an adjustment to the water pressure switch. Do you agree and if so, where is it located and how do I adjust it. If you do not agree, what do you suggest? Show More Show Less
What should I do if I find a fault in my Raypak heater?
Power found at either PV or MV at the incorrect time. 1. Turn power OFF and disconnect Ignition Wire and Gas Valve wires from board. 2. Power ON and watch for spark at module. 3. If no spark, turn power OFF, and replace board. 4. If spark is observed, turn off power and reconnect wires. The unit should fire.
When to replace jumper thermostat on Raypak boiler?
Jumper thermostat, replace with new if heater fires. If power to toggle switch, but not through switch, replace. If power to relay, but not operating, replace. Thermostat in “ON” position causes relay and pump to operate, but heater does not fire.
How does a Raypak pool and spa control work?
2) If three lockouts occur in one heat demand, control goes into “hard lockout” and power must be removed and re-applied to reset. Your heater is equipped with a microprocessor-controlled thermostat that controls the pool or spa temperature by measuring the temperature of the water coming back through the heater.