What does HS mean on Hayward pool heater?

What does HS mean on Hayward pool heater?

HS Water Temperature Sensing Error A) Inlet water temperature sensor is reporting a temperature in excess of 104°F. Normal operation resumes 2 minutes after inlet water temperature sensor reports temperatures of 104°F or less. This error functions in both normal and remote thermostat modes.

What does H5 mean on a Hayward heater?

We a “service” message on our Hayward gas heater h250fnd also error message HS or H5. the code is HS. it means that the maximum allowed temperature has been reached too fast. there are a few situations that may cause this. restricted flow is the most common.

What does HS mean on pool heater?

HS code is telling you that the water output temp is too high. The code does not necessarily mean the sensor is bad but, is instead telling you there is a problem in the operation of the heater.

What does f1 mean on a pool heater?

it stands for ignition failure. If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. Automatic reset is 60 minutes. Aug 08, 2014 • Hayward Pool & Spa.

What does if stand for on Hayward pool heater?

The Hayward heater LED display will show a diagnostic fault code of “IF” which stands for Ignition Failure. Undetected gas pressure problems if not investigated properly may result in unnecessary replacement and servicing of your Hayward Pool Heater.

What kind of gas heater does Hayward use?

Hayward Universal H-Series ASME gas heater is the universal energy efficient remedy for any new or existing commercial pool or spa application. Saline C Series eliminates the need for linking up multiple cells – lowering installation costs from a smaller footprint. It is NSF certified and designed to produce up to 6lbs with the Saline 6.0.

Where can I find parts for my Hayward pool?

PartsWarehouse.com is an independent re-seller of OEM parts, not affiliated with Hayward. Find any Hayward part in 3 Clicks! Model Type? Pool Cleaners Pumps Filters Heaters Lights Valves Jets

What kind of pump does Hayward commercial use?

Hayward® Commercial HCP self-priming pumps provide a technologically advanced alternative to traditional Bronze or Cast Iron Pumps. They’re quiet, efficient, easier to install & don’t rust. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. IE9 and older versions are not supported.

What does HS code mean on Hayward pool heater?

Has anyone had and experience with the HS code for Hayward heaters. Any ideas or advice will be appreciated. Thanks in advance. HS code is telling you that the water output temp is too high. The code does not necessarily mean the sensor is bad but, is instead telling you there is a problem in the operation of the heater.

How old is the Hayward H400 pool heater?

The pool is equipped with a Hayward H400 FDN gas heater. It is 4 years old. I was first getting a CE code. I replaced display board and it went away. Heater is firing up and after 1 minute of running it throws a HS Code and abruptly shuts off.

How to troubleshoot a universal H series blower?

1. The control checks for open Blower Vacuum Switch 2. Blower starts pre-purge cycle as the igniter heats up (20 Sec). 3. The Control checks for a closed Blower Vacuum Switch. 4. At proper Igniter temp a 4 second trial begins. Gas valve opens and monitors flame sense. The blower will turn off for one second. The

Why does my pool heater have a lo code?

The heater will display a LO code when water flow does not meet the minimum required by the heater. I have a variable speed pump. On low heater will not run. Pump has to be at least 2000 rpm.

You Might Also Like