What does EC code mean on hot tub?

What does EC code mean on hot tub?

Ecn or Ec Message Ecn or Ec is Alternating with Temp: The Spa is Operating in the “Economy” (Ecn or Ec) Heating Mode. The Water Temperature is sampled Only during Programmed Filter Cycles. The Heater will only operate and Heat up to Set Temperature during the Filter Cycles.

Why does my hot tub keep going to Economy mode?

The temperature of the hot tub will be reach & maintained when in standard mode. Economy. The hot tub will only use the heater when the spa is in “filter mode” and the water has encountered a drop in temperature below the standard thermostat setting. Also, what setting should hot tub be on?

What is EC mode on hot tub?

EC: Economy – Spa will heat ONLY during filtration settings. It will heat to the set temperature and the spa may cool down until the next filtration cycle. Heating will resume again in 12 hours.

What to do if your spa has a sensor balance error?

Step 10: Once the spa has been powered up and running for a few minutes, there should be no more sensor balance error codes displayed. If the Sensor Balance Error continues, please contact us at 1- (877)-347-7727 or create a Support Ticket by clicking HERE to inquire about further assistance.

What to do if your hot tub has an error code?

In some instances it may be more prudent to contact a local hot tub service company to assess and repair the spa pack as some diagnose procedures require special equipment. Please note that the Balboa Error Codes cover all circuit board manufactured by Balboa including Cal Spa, Marquis Spa, Master Spa and many others.

Where are the sensors on a Balboa hot tub?

Note: The below images refer to a Toronto Spa for the location of the control system. Placement varies from spa to spa, but in any case it will be located along the same side of the hot tub as the main control panel. Step 3: Locate the heater’s sensor wires and trace them to where they plug into the circuit board (pictures below).

What are the error codes on the Balboa spa?

Balboa Spa Side Error Codes pd Power supply, unit running on battery ba OH Sensors reading 112-118° F. OHH Overheat. Spa has shut down. One sensor OHS Overheat. Spa has shut down. One sensor

Step 10: Once the spa has been powered up and running for a few minutes, there should be no more sensor balance error codes displayed. If the Sensor Balance Error continues, please contact us at 1- (877)-347-7727 or create a Support Ticket by clicking HERE to inquire about further assistance.

Note: The below images refer to a Toronto Spa for the location of the control system. Placement varies from spa to spa, but in any case it will be located along the same side of the hot tub as the main control panel. Step 3: Locate the heater’s sensor wires and trace them to where they plug into the circuit board (pictures below).

What does sensor out of balance mean on M7 hot tub?

Same for Sensor B error. The 2 sensors may be out of balance if SnS appears. The the pump ON just before heater ON, the sensors differ more than 2F degrees, that means one or both sensors are several degrees off so the sensor set must be tested (see M7 technical service manual). A verified sensor out of balance occurs when SnS is flashing.

What to do if your hot tub sensor is not working?

The sensor connected to “A’ is not working and the system is shut down. Check for loose plug or damaged wires. Switch sensors A and B at the board (for techs). If message changes to SnB or SENSOR B SERVICE RQD, then replace sensor, if not the problem could be with the circuit board. Same for Sensor B error.