What does CE mean on a pool heater?
CE code indicates “Communication Error”. Problem is communication between integrated control board and display board.
Why does Raypak pool heater display error : Water SW open?
The heater will only operate for a short time before it cuts off and displays the message “Water Sw Open.” I googled this and most seem to advise an adjustment to the water pressure switch. Do you agree and if so, where is it located and how do I adjust it. If you do not agree, what do you suggest? Show More Show Less
What kind of pool heater does Raypak use?
We bought a new heater this season, a Raypak 206,000 BTU NG Electric Heater RHM-15-9962. It heated the pool nicely earlier in the week, but we turned it off when a cool spell was forecast. This morning I tried to turn it on and I get this error message: “Rollout SW Open”.
When does rollout SW open on Raypak heater?
I appreciate the help. Here is what I found in the manual: Roll Out Sw Open – Rollout Switch – verify gas pressure, combustion air, blocked heat exchanger, proper vent size/connections, high wind conditions. The rollout switch is activated when something like wind causes the flames to shoot out towards the front of the unit.
Why does my pool heater say Water SW open?
garrygoeson : I’m sorry to hear that. Usually, the Water sw open code is related to a flow problem, and may not be a fault with the heater. PLCUSTOMER: Right, I know there is some kind of regulator, for lack of a better word, and not sure if that is related to this, but I had problems with it on my last heater and the pool people removed it.
When does the fault code appear on a Raypak heater?
Raypak Heater Fault Code Guide 1 Water temperature is below 36F or above 110F 2 If the two thermistors are more than 2 degrees apart, the SNS code will appear. 3 Loose or corroded connection at P1. 4 If the sensor is not mounted all the way into the JACO fitting on the header, it may give a false reading.
What is the code for a gas water heater?
The water heater must be installed according to all local and state codes or in the absence of local and state codes, the “National Fuel Gas Code”’ ANSI Z223.1(NFPA 54)- current edition. INSTALLATION OF RESIDENTIAL GAS WATER HEATER See Labels and Installation Instructions and Use & Care Guide for clearances.
What to do if your Raypak pool heater goes bad?
1. Possible excessive water temperature in the tube bundle. Once heater cools, high limits resets automatically. 2. Check for blockage in tubes. 3. Check for low water flow. 4. Check Unitherm governor- replace if necessary 1. Possible excessive water temperature in the tube bundle. Once heater cools, high limits resets automatically. 2.
What should the pressure be on a water heater?
Dripping Temperature & Pressure Relief Valve Check water supply pressure. In closed systems, the supply pressure should not exceed 80 psi (in a 24 hour cycle). If the pressure exceeds 80 psi, install a pressure reducing valve in combination with a properly sized thermal expansion tank (pp. 35-36 & 37).