How to troubleshoot ignition failure on Raypak 407A?

How to troubleshoot ignition failure on Raypak 407A?

Click to expand… The troubleshooting steps for the electronic pilot style is on page 45 of the manual I linked to. Note that is says “on some models the ignition module shuts of gas to pilot if the pilot doesn’t light and power to the heater must be interrupted to reset”.

Why does my Raypak pool heater not ignite?

Now the ignite will spark (with the code on the unit as SPK), but even with a lighter, the unit does not flame up. I suspect that there is no gas going to the burners. Anyone have similar issues? Could it be the gas regulator (I’ve turned it off and on many times), or a clogged gas line. Of course, we have company coming over tomorrow!

When does the pilot light on a Raypak?

The pilot only lights when it’s in spark mode. It’s very visible when lit. The pilot assembly is where you would see if it is lit or not. Here is the manual for the system. You can look at the parts diagram and it will show you where the pilot assembly is located.

Click to expand… The troubleshooting steps for the electronic pilot style is on page 45 of the manual I linked to. Note that is says “on some models the ignition module shuts of gas to pilot if the pilot doesn’t light and power to the heater must be interrupted to reset”.

Do you need to troubleshoot a Raypak pool heater?

Effective Raypak pool heater troubleshooting is all about knowing what to look for, and what the signs mean. Although all pool heat pumps need maintenance to maintain performance, a bit of troubleshooting can save you a lot of time. When you know what’s causing a problem with your pool heater, then fixing it is way simpler.

Is the raypack p-r406a-en-C Control Board too big?

This sensor did not have the correct adapter to fit both the original or the new control board for the Raypak Model P-R406A-EN-C; manufactured after 2004. The adapter is too large and does not fit the control board. However, the manual clearly lists this part number as the part for this model.

Where is the pilot burner on a Raypak?

Never worked on a raypak, but i’ve worked on a lot of burners… I assume you have access to the gas valve if you are in the panel changing the board. Off of the valve there should be a small, usually aluminum pilot tube – follow it and you should find the pilot burner. It is the electronic ignition model.

Why does my Raypak heater not light the pilot?

I turn it on and hear the ignition trying to light the pilot light but the pilot does not light. Clogged orifice? If so, can these be unclogged with a lighter or do they need to be disassembled?

Where is the pilot Assembly on a Raypak?

The pilot assembly is where you would see if it is lit or not. Here is the manual for the system. You can look at the parts diagram and it will show you where the pilot assembly is located. Thanks, thats a much better manual than I have.

What should the spark be on a Raypak pool?

Note: you should get ~28-32V between the PV and the MV/PV connections on the gas valve during pilot IGN. No spark AT THE point of ign.

What to do if your Raypak heater is not working?

If we don’t have a solution or do not address your particular issue, it’s always best to contact Raypak directly. The majority of Raypak heaters will have a digital readout. The digital readout helps pool owners read error codes on the actual heater.

Why is my Raypak pool light not working?

Clogged orifice yes can be cleaned but if it is dirty or otherwise clogged, the pilot assembly may also be corroded to the point you may break it taking it apart. New assembly is < $100. Stuck or failed PV solenoid (gas valve) or could also be a bad or chewed wire to the gas valve.

The pilot only lights when it’s in spark mode. It’s very visible when lit. The pilot assembly is where you would see if it is lit or not. Here is the manual for the system. You can look at the parts diagram and it will show you where the pilot assembly is located.