How to troubleshoot a white Rodgers intelle-vent control?
Troubleshooting 1. Cycle power to the water heater off for 10 seconds and then back on. 2. If the above step did not clear the error, the Intelli-VentTM control must be replaced. Try to do this and if it does not clear it the code the high limit is integrated with the control valve…so you must replace it if it does not clear.
How to troubleshoot an intelli vent water heater?
1 Inadequate or no earth ground sensed by the Intelli-Vent™ control. 1 Ensure the wall outlet is properly grounded. 2 Ensure all ground connections/wires on the water heater are secure. 2 Power supply to Intelli-Vent™ control has reversed polarity. 1 Ensure the wall outlet is properly wired.
What is the temperature adjust button on Intelli vent?
Top connect models are in use currently. Temperature adjust buttons Temperature adjust buttons must be pressed together for one second to “wake up” the control in order to view or change temperature settings. INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 2005 3 of 24 INTELLI-VENT™ OPERATION
What happens when all lights come on on Intelli vent?
All lights on the control will come on for about 1 – 5 seconds. All lights will then turn off. If the stored water is above 70°F (residential) and the control setting has not been increased from it’s factory setting, nothing more will happen.
Troubleshooting 1. Cycle power to the water heater off for 10 seconds and then back on. 2. If the above step did not clear the error, the Intelli-VentTM control must be replaced. Try to do this and if it does not clear it the code the high limit is integrated with the control valve…so you must replace it if it does not clear.
What do you need to know about the Intelli vent?
INTELLI-VENT TROUBLESHOOTING GUIDE Technical Training Department Ashland City, Tennessee © 2005 1 of 24 INTELLI-VENT™ FEATURES The Intelli-Vent™ is a combination control incorporating all temperature control, ignition control, blower and ignitor control, flame sensing, and gas regulation into a single device. Advanced Diagnostics – Error Codes
When to replace the Intelli-vent hot water blower?
B If pressure switch contacts are open and all wiring is correct – turn the power off for 10-20 seconds then on again to clear the error code – if the error code persists replace the Intelli-Vent™ control. 4 Pressure switch circuit remains open longer than 5 seconds after the blower is energized. Blower may run continuously in this condition.
What are the Erro codes on Intelli vent?
Advanced Diagnostics – Error Codes The Intelli-Vent™ features advanced diagnostics with 15 specific error codes including reversed polarityand inadequate groundingnotification. Diagnostic information is conveyed via 6 LED lights on the control. These erro r codes will help diagnose and repair the wate r heater quickly and accurately.