How does a Max E therm heater work?

How does a Max E therm heater work?

Installation Installation Instructions HEATER DESCRIPTION Figure 1 is a diagram of the heater showing how it operates. Precisely matched orifice plates meter the air and gas into the mixer. The blower draws the air and gas through the mixer and forces it into the burner’s flame holder. Section 2.

How to troubleshoot Sta-Rite Max E therm pool heater?

Troubleshooting 38 Burner / Heat Exchanger Troubleshooting 45 Related Manuals for STA-RITE Max-E-Therm® Swimming Pool Heater STA-RITE Sr200na, Sr200lp,, Sr333na, Sr333lp,, Sr400na, Sr400lp Owner’s Manual

Where is the flame holder on a mastertemp pool heater?

The Burner System of the MasterTemp/Max-e-Therm heaters is one single burner, called the Flame Holder, shown right. The burner is located in the center of the combustion chamber, wrapped by the circular copper heat exchanger tubes.

Do you need to use a draft hood with a Max E therm?

Follow venting instructions exactly when installing heater. Do not use a drafthood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. Page 10: Section 2. Installation Section 2.

How to install a Max E therm pool heater?

Max-E-Therm® swimming pool heater pdf manual download. Also for: Max-e-therm sr200na, Max-e-therm sr200lp, Max-e-therm sr200hd, Max-e-therm sr333na,… Sign In Upload Download Share URL of this page: HTML Link: Add to my manuals Add Delete from my manuals Bookmark this page

How to download Sta-Rite Max-E-therm installation manual?

View and Download STA-RITE Max-E-Therm® operation & installation manual online. 120/240 VAC NATURAL GAS/LP GAS Pool & Spa Heater. Max-E-Therm® swimming pool heater pdf manual download. Also for: Max-e-therm sr200na, Max-e-therm sr200lp, Max-e-therm sr200hd, Max-e-therm sr333na,… Sign In Upload Download Share URL of this page:

What kind of PVC pipe does Max E therm use?

The Max-E-Therm is a lightweight, efficient, induced-draft, gas fired high performance pool and spa heater that can be directly connected to schedule 40 PVC pipe, [schedule 80 CPVC for ASME models only]. Section 1.

Follow venting instructions exactly when installing heater. Do not use a drafthood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. Page 10: Section 2. Installation Section 2.

You Might Also Like