How do you use Atwood Hydro Flame furnace thermostat?

How do you use Atwood Hydro Flame furnace thermostat?

How do you use Atwood Hydro Flame Furnace?

  1. Charge your RV’s battery up and turn the Atwood Hydro-Flame furnace’s gas valve on to the “pilot” position.
  2. Light a match while pushing and holding the gas valve.
  3. Allow the gas flame to burn for a moment before switching the gas valve over to the “on” position.

How to turn off hydro flame TM furnace lighting?

Turn off all electric power to the appliance. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. Open the control access panel. Turn off switch (circuit breaker or manual switch) to the OFF position. Wait (5) minutes to clear out any gas.

How to convert a hydro flame furnace to an alternate fuel?

A conversion kit has been supplied by the manufacturer to convert the furnace to an alternate fuel. . Shut off Gas and Electrical at main sources. 1 2 . Remove vent assembly from burner area. Disconnect the gas line. I-JD model remove Inlet Manifold. 3. 4. Remove cover and (4) screws holding burner box assembly 5.

Where is the electrical switch on a hydro flame furnace?

Open the access panel to turn off electrical switch. Models with no exterior access door have a switch located outside of the furnace on the left side. Close the control access panel. OFF Black wire White wire Thermostat Any wiring replacement must be replace with equivalent type 105’C wire or better. SERIES.

Turn off all electric power to the appliance. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. Open the control access panel. Turn off switch (circuit breaker or manual switch) to the OFF position. Wait (5) minutes to clear out any gas.

A conversion kit has been supplied by the manufacturer to convert the furnace to an alternate fuel. . Shut off Gas and Electrical at main sources. 1 2 . Remove vent assembly from burner area. Disconnect the gas line. I-JD model remove Inlet Manifold. 3. 4. Remove cover and (4) screws holding burner box assembly 5.

Open the access panel to turn off electrical switch. Models with no exterior access door have a switch located outside of the furnace on the left side. Close the control access panel. OFF Black wire White wire Thermostat Any wiring replacement must be replace with equivalent type 105’C wire or better. SERIES.