How do you reset aqua rite?

How do you reset aqua rite?

To reset, move the switch to ‘Off’ and then back to ‘Auto’. Wait for the relay to click (5 to 10 seconds). When the instant salt level is stable (and the negative sign still present), slide switch to ‘Super Chlorinate’ and back to ‘Auto’. It takes about 30 seconds for the unit to settle back on the default reading.

What do the numbers on LCD mean on aquarite control?

Our pool was built about 6 weeks ago. It is 18 X 32 ft (~20000gal) vinyl linered salt water filter (SWG) automatic chlorine generator with Aquarite (Goldline) control box. What do each of these numbers mean when we press the diagnostic button. With each push of the button, the numbers cycle Output knob is set at 40%.

What should salt level be on Hayward Aqua rite?

Press and hold the diagnostic button for 3 to 5 seconds. The LED light should go out. Your salt level is between 2500-2600 parts per million (ppm). Your chlorine generator is still producing chlorine at the moment, which is a good thing.

What’s the best way to troubleshoot an aqua rite cell?

(GLX-CELLSTAND) Step 1: Use a water hose to dislodge small debris. Step 2: Use a non-metal (plastic or wood), non-abrasive tool to dislodge minor calcium buildup and small debris. Step 3: Use a solution of water and Muriatic acid. Stand the cell vertically in the solution. M’x 1 part acid to 4 parts water.

How to set Turbo cell size on Hayward Aqua rite?

How To Set Your Turbo Cell Size Slide your main switch to the AUTO position. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. Push the diagnostic button until “T-XX” appears on the display.

Where can I find the Aqua rite diagnostics manual?

Aqua Rite & Aqua Rite XL Diagnostics Manual AQUA RITE ELECTRONIC CHLORINE GENERÀTOR CELL Turbo Cell & Control Electronics Software Revision 1.50 O HAYWARD Copyright 2009 Hayward Industries Inc.

What is the digital number on Aqua rite chlorinator?

The is the digital number that corresponds to the black dial underneath the LCD display. Turn the dial to the right increases the output % and turning to the left decreases the output %. 6. Instant Salt Reading (ISR)

(GLX-CELLSTAND) Step 1: Use a water hose to dislodge small debris. Step 2: Use a non-metal (plastic or wood), non-abrasive tool to dislodge minor calcium buildup and small debris. Step 3: Use a solution of water and Muriatic acid. Stand the cell vertically in the solution. M’x 1 part acid to 4 parts water.

When do I need to replace my Aqua rite transformer?

The readings should be 2.0-2.9 Ohms. If the readings of either of the two measurements are not 2.0 — 2.9 Ohms, the transformer is faulty and should be replaced If measurements are OK, go to step F. O HAYWARD No LED’ Verify 18-33 VDC between black & red wires on main board step G DCV OFF . ON If no/low voltage replace rectifiers.