How to Fix Holes in Iron Pipes

  1. Put on a dust mask, safety glasses and work gloves.
  2. Remove loose metal debris and rust from the pipe at the area of the hole, using a steel putty knife.
  3. Use the putty knife to fill the hole with cast-iron patching compound.

When to replace a section of cast iron pipe?

One of the biggest problems with the cast iron pipe is that it tends to break or corrode. Once it is past a few years old, it can easily deteriorate so badly that it develops water leaks and other problems. One solution to this is to replace your old cast iron pipe with a section of PVC pipe.

Where to put new cast iron sewer line?

We suggested rerouting the pipe from the kitchen sink line underground into a trench outside of the house — not under the house under the slab. This put the pipe in the front yard instead. Meaning? The $6000 they paid the previous company and the 12 feet of new pipe was a complete waste.

How old are cast iron sewer pipes in North Texas?

Meaning most people’s cast iron systems in the North Texas area are more than 35 years old. So with that mind, it’s more than likely any system made of cast iron will need to be replaced in the next five to 20 years (closer to five than 20, by the way).

Are there problems with cast iron drain pipes?

However, even houses built in the 1960s are starting to have trouble with their cast iron pipes. One common problem with older homes is that the trees in their yards are also old. In many cases, they have roots that reach all the way down to the pipes.

One of the biggest problems with the cast iron pipe is that it tends to break or corrode. Once it is past a few years old, it can easily deteriorate so badly that it develops water leaks and other problems. One solution to this is to replace your old cast iron pipe with a section of PVC pipe.

Can you replace cast iron drain pipe with ABS?

Here I will be replacing the cast iron drain system to the master bathroom with ABS drain piping. I will be cutting the cast iron out from the base at the foundation and joining the old to the new. ALWAYS CONSULT A PROFESSIONAL PLUMBER BEFORE ATTEMPTING REPAIR. Loading…

We suggested rerouting the pipe from the kitchen sink line underground into a trench outside of the house — not under the house under the slab. This put the pipe in the front yard instead. Meaning? The $6000 they paid the previous company and the 12 feet of new pipe was a complete waste.

Meaning most people’s cast iron systems in the North Texas area are more than 35 years old. So with that mind, it’s more than likely any system made of cast iron will need to be replaced in the next five to 20 years (closer to five than 20, by the way).