How do you calibrate a Jandy AquaPure?

How do you calibrate a Jandy AquaPure?

Press and hold the ‘Pool Temperature’ (‘D’) key for 15 seconds. The system will beep when the button is pushed, it will beep again after 10 seconds, and again after 15 seconds. Release the key after the third beep.

How do you calibrate a pool Temperature sensor?

To calibrate the water sensor:

  1. Switch on the spa or pool filter pump.
  2. Place the thermometer in the spa or pool, depending on the system model number.
  3. Take an accurate temperature reading.
  4. At the Indoor Control Panel, press the buttons next to the Water Temp label to adjust the temperature up or.

How to troubleshoot a Jandy aquapure power supply?

If salinity is low, more salt may need to be added. Clean the cell if it is dirty or clogged. Check that the unit is connected to a power supply and the pump is switched on. Fully insert into the connector the ribbon cable between front and back PC board. Properly connect the connector at the white plug between the transformer and back PC board.

What to do if your aquapure has water leak?

• Be sure that the cell positioned properly and the DC cord is connected properly to the cell. • Check the flow sensor cable and cell cable for damage (chewed on by an animal, weed-wacked, etc.). • Look for water leaks at the cell and flow sensor.

What does an aquapure do in a pool?

AquaPure is a salt chlorine generating system used to sanitize your pool, using a closed-loop water-softening system.

What should the chlorine content be on a Jandy aquapure?

Chlorine stabilizer content should be 50 to 75 PPM. For every 50 pounds of salt, 1.25 pounds of stabilizer should be added. Increase the system’s daily operating time. Increase chlorine production by pressing the “chlorine production rate adjustment” button. Enable “boost” mode and run for 24 hours. Press the “test salinity” button.

• Be sure that the cell positioned properly and the DC cord is connected properly to the cell. • Check the flow sensor cable and cell cable for damage (chewed on by an animal, weed-wacked, etc.). • Look for water leaks at the cell and flow sensor.

How to change the salinity reading on aquapure?

•Press and release the “Temperature “ button within 5 seconds to enter the salinity calibration screen. •The system will display the salinity reading, press the up arrow to increase the reading and the down arrow to decrease the reading. •When the proper reading is reached press the “Temperature” button within 5 seconds to store it in memory. 15

How do I Reset my aquapure flow sensor?

Connect it to the unit and place it in a bucket of the pool water to compare readings. Note-The unit must have the power turned off before either the old or new flow sensor can be installed. Each time a flow sensor is unplugged and plugged back in again the computer inside the unit must be reset by turning the power ‘off’ and then ‘on’.

How do you calibrate an aquapure water heater?

•Press the “Salinity” button and hold it until it beeps 3 times. The system will beep when you push it and then at 5 seconds and again at 10 seconds. Release the button after the 3rdbeep. •Press and release the “Temperature “ button within 5 seconds to enter the salinity calibration screen.