How do I put Jandy Jxi in remote mode?

How do I put Jandy Jxi in remote mode?

Enter Remote Thermostat in Service Set-up Mode (#3 from Service Setup Mode functions). Display will show REMOTE on the second line. The UP/DOWN arrows will toggle to options: ‘OFF’, ‘HI-LO-COM’, or ‘REMOTE T-STAT’. For Aqualink RS connection use ‘REMOTE T- STAT’, then MENU to save selection.

Why is my Jandy JXI pool heater not working?

Then the control board checks for hi/lo temp, water pressure, vent fire sensor, then it issues “call for heat” to the ignition control. Then the blower starts and the ignition module checks pressure senor. After 15 sec the igniter is turned on and you’ll see a faint then strong orange glow through the igniter window.

Is there a check IGN control fault on Jandy LXI?

I’m getting a CHECK IGN CONTROL fault on my Jandy LXi. It will turn on and attempt to ignite a few times in 4 minutes, but it’s unable to start. Step 15 – I do not know how to check if the igniter is glowing, so I assumed NO and proceeded w/ the boxed steps.

What happens when the igniter does not work on Jandy pool?

During the 7 seconds the ground for the igniter is interrupted and the igniter becomes the flame sense signal source. If the igniter does not function or gas does not flow and get ignited you don’t get flame sense detected through the ground circuit from the burners.

Why is the gas valve open on my Jandy pool?

This just means during the ignition cycle 110 v is supplied to the flame sense rod and if a flame is present a tiny signal (couple millionths of amp) flows to the burner base and back to the Fenwal circuitry to prove flame and leave the gas valve open. You should also have a view port that allows you to see the igniter glowing.

Then the control board checks for hi/lo temp, water pressure, vent fire sensor, then it issues “call for heat” to the ignition control. Then the blower starts and the ignition module checks pressure senor. After 15 sec the igniter is turned on and you’ll see a faint then strong orange glow through the igniter window.

I’m getting a CHECK IGN CONTROL fault on my Jandy LXi. It will turn on and attempt to ignite a few times in 4 minutes, but it’s unable to start. Step 15 – I do not know how to check if the igniter is glowing, so I assumed NO and proceeded w/ the boxed steps.

What does it mean when Jandy says check ignition fault?

Jandy pool heater lxi model says check ignition fault what… Customer Question Jandy pool heater lxi model… Jandy pool heater lxi model says check ignition fault what does this mean ? Submitted:7 years ago. Category: Pool and Spa Show More Show Less Ask Your Own Pool and Spa Question Share this conversation Answered in 1 hour by: 3/29/2014

During the 7 seconds the ground for the igniter is interrupted and the igniter becomes the flame sense signal source. If the igniter does not function or gas does not flow and get ignited you don’t get flame sense detected through the ground circuit from the burners.

You Might Also Like