How do I fix the SA code on my hot tub?
Hear this out loudPauseYou can try unplugging the hot tub sensor to fix the Sn error code. Wait for a few minutes, then plug it back in. Don’t forget to turn the power off before attempting this. You could also clean or replace the filter cartridges, check whether there are any broken valves, or there’s something stuck in the skimmer.
How do you get Balboa out of sleep mode?
Hear this out loudPauseTO EXIT REST MODE:- Press Temp, then press light repeatedly until ‘MODE’ appears in the LCD. Toggle between READY and REST by pressing temp. Press light or wait for 10 seconds to go back to the Main Screen.
What’s the LTER time for the Balboa 500Z?
The default fi lter time is 2 hours for non-circ systems and 4 hours for circ systems. To program, press “Temp,” then “Jets 1.” Press “Temp” to adjust. Press “Jets 1” to exit programming. For non-circ systems, low-speed pump 1 and the ozone generator (if installed) run during fi ltration.
Why is there a diagnostic message on my Balboa?
Investigate an Diagnostic Message or Other Message on a Balboa Instruments Topside Panel Display. There is no guarantee expressed or implied that this technology can detect all instances of a real or potential problem with the equipment. There may be conditions that exist in which the spa control system will be unable to detect these conditions.
Where can I find the Balboa BP troubleshooting manual?
42211 C Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group. Balboa’s BP Troubleshooting & Service Manual SPA CONTROL SYSTEMS PANELS60 Hz BP500 BP2000G1 TP900, TP800, TP600, TP400 THIS MANUAL COVERS THE FOLLOWING:
How to check spa panel messages on Balboa direct?
1. Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode. 2. After about 45 Seconds, Check for Error Messages on the Topside Panel Display. If there is No Error Message, Select “No Error Message” Below. If there is Now an Error Message, select Message Other than CrC or CHKSUM FAIL below.
The default fi lter time is 2 hours for non-circ systems and 4 hours for circ systems. To program, press “Temp,” then “Jets 1.” Press “Temp” to adjust. Press “Jets 1” to exit programming. For non-circ systems, low-speed pump 1 and the ozone generator (if installed) run during fi ltration.
Where to find the diagnostic message on Balboa Instruments?
Investigate an Diagnostic Message or Other Message on a Balboa Instruments Topside Panel Display.
What to do when there is no error message on Balboa?
If there is No Error Message, Select “No Error Message” Below. If there is Now an Error Message, select Message Other than CFEor CONFIG ERROR below or contact your Dealer or Service Organization. The “CFE” or “CONFIG ERROR” Configuration Error Appears to have been Corrected or is Intermittent.
1. Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode. 2. After about 45 Seconds, Check for Error Messages on the Topside Panel Display. If there is No Error Message, Select “No Error Message” Below. If there is Now an Error Message, select Message Other than CrC or CHKSUM FAIL below.