How do I calibrate my Hayward Aqua Plus?
With the pump running, take the power switch down to the “Off” position, and then back up to “Auto”. You should hear a click within 10 or 15 seconds. When you do, press the diagnostic button five times in a row. The system will go through a recalibration process.
How to fix high amps on Hayward T-15 cell?
People have reported that the “No Cell Power Fix” does indeed fix the high amps problem as well. See here: But also double check that the setting in the AquaLogic is for the T-15 and not the T-9 cell. I have done the K-1 fix for the no cell power.
Why is my Aqua rite cell light not working?
It is only 3 years old so can’t imagine it would already be gone out. With Leslies saying that the cell is ok, it appears as if the Aqua Rite isn’t reading the salt level properly and therefore isn’t generating chlorine.
What should the SWG be on a Hayward T-15?
Under normal circumstances, Hayward SWG should not exceed 31 VDC when the switch is in OFF position or when cell is not generating. Try to reseat the Display board and make sure the pins are inline with the mating connector in the motherboard. It was not a typo… it now reads +40.62…… earlier it showed -40.62.
How to set Turbo cell size on Hayward Aqua rite?
How To Set Your Turbo Cell Size Slide your main switch to the AUTO position. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. Push the diagnostic button until “T-XX” appears on the display.
What can you do with an aqua plus?
The Aqua Plus can control pumps, valves, lighting, heaters, and chlorination. Although the Aqua Plus is easy to use, it is important to completely read through this operating manual before attempting to operate the control. NOTE: This manual assumes that the Aqua Plus has been wired and configured according to the Installation Manual.
How To Set Your Turbo Cell Size Slide your main switch to the AUTO position. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. Push the diagnostic button until “T-XX” appears on the display.
What’s the best way to troubleshoot an aqua rite cell?
(GLX-CELLSTAND) Step 1: Use a water hose to dislodge small debris. Step 2: Use a non-metal (plastic or wood), non-abrasive tool to dislodge minor calcium buildup and small debris. Step 3: Use a solution of water and Muriatic acid. Stand the cell vertically in the solution. M’x 1 part acid to 4 parts water.
What do you need to know about Hayward Aqua plus?
The Hayward Aqua Plus is a multifunction pool controller used to fully manage your pool/spa system. The Aqua Plus can control pumps, valves, lighting, heaters, and chlorination. Although the Aqua Plus is easy to use, it is important to completely read through this operating manual before